CyberPower
CyberPower OL2200RTXL2UN 2200VA/1800W, 0.9PF, Pure Sine Wave, 2U, NEMA 5-20P, 10 ft cord
Prevent business interruptions and safeguard mission-critical enterprise network equipment.
The CyberPower OL2200RTXL2UN is a rack/tower UPS with double conversion topology. It provides sine wave output to critical applications and equipment that require seamless power correction. The Extended Battery Module (EBM) expands runtime, and Fast Charge Technology restores full backup power faster. This model comes with an extendable LCD control panel, Smart Battery Management charging technology, and energy-saving GreenPower UPS™ ECO Mode.
The OL2200RTXL2UN offers generator compatibility and delivers clean AC power with zero transfer time. A factory installed RM card allows remote management and configuration of the UPS via a standard web browser, command line interface (CLI), or network management system (NMS). Its sine wave output keeps sensitive equipment working by preventing unnecessary shutdowns that can occur with simulated sine wave output.
With a $400,000 lifetime connected equipment guarantee and a three-year warranty, you can trust CyberPower’s commitment to high quality.
Double-Conversion Topology
- Provides consistent, clean, and nearly perfect power, regardless of the condition of the incoming power. With the conversion to DC power, the UPS has a zero millisecond transfer time to battery power when utility power is lost. Designed for high-end system components, corporate servers, lab equipment, and other sensitive electronic devices.
Sine Wave Output
- Keeps sensitive equipment with Active PFC working by preventing unnecessary shutdowns caused by gaps from simulated sine waves.
PowerPanel® Business Edition Software
- Provides tools for easy remote monitoring and managing of the UPS and automates shutdown of multiple devices when needed.
RMCARD205
- Is a full-featured network management card. It enables remote management via a standard web browser, command line interface (CLI), or network management system (NMS) connection.
LCD Control Panel
- Displays UPS status data and configures operating settings from up to 10 ft. away (DB26 cable not included). The LCD control panel displays and allows configuration of IP address settings when an RMCARD205 is installed.
Extended Battery Module (EBM)
- Extends runtime by adding up to 10 EBMs.
Fast Charge Technology
- Allows UPS batteries to return to full capacity more rapidly by utilizing a built-in charger. Restores charge from 0-90% within 4 hours regardless of the number of EBMs.
Smart Battery Management (SBM)
- Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process.
GreenPower UPS™ ECO Mode
- Improves UPS efficiency up to 95% reducing electrical and cooling costs.
Hot-Swappable Batteries
- Keep equipment running by eliminating downtime during UPS battery replacement.
Upgradeable UPS firmware
- Manages the unit’s features and functions.
Critical & Non-Critical Load Banks
- Maximize the output of the UPS by setting non-critical loads to shut off allowing additional runtime for critical load outlets.
Emergency Power Off (EPO)
- Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.
Generator Compatible
- Ensures a stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.
Converter Mode
- Provides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50Hz or 60Hz output on the LCD control panel.
USB & Serial Connectivity
- Enables full integration with built-in power management and auto shutdown features on Windows, Linux, and VMware systems through a HID-compliant USB port and Serial port.
EMI/RFI Filters
- Prevent electromagnetic and radio frequency interference to ensure clean power for connected equipment.
Data Line Surge Protection
- Prevents power surges that travel through telephone and Ethernet lines from causing damage to your equipment
Audible Alarms
- Identify when the model is running on battery power, overloaded, or has a low battery.
Resettable Circuit Breaker
- Interrupts an electric current in a circuit when the current becomes too high.
LED Status LightsIndicate Power On, Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery.
Rack/Tower Versatility
- Allows for horizontal rack or vertical tower installation.
Three-Year Warranty
- Gives you peace of mind knowing we will repair or replace a defective UPS system (including batteries) within three years of the purchase date. See warranty for details.
Connected Equipment Guarantee
- Affirms we will repair or replace properly connected equipment if it is damaged by a power surge.
What’s In The Box
UPS system, User Manual, Registration card, (2) Rackmount rails, (2) Hanging brackets, (2) Rackmount ears, USB communication cable, Serial interface cable (RS-232), (8) M5X7L black flat head screws, (12) M5X12L black pan head screws, (6) M5X6L silver pan head screws, (8) Plastic washers, (12) Screw hole dust covers, (12) Rubber pads, Software download card
WARNING:
This product can expose you to chemicals including Styrene, which are known to the State of California to cause cancer, and Bisphenol A (BPA), which are known to the State of California to cause birth defects or other reproductive harm. For more information go to http://www.P65Warnings.ca.gov .
General | |
---|---|
Energy Saving | ECO Mode Efficiency >95% |
Energy Star Certified | Yes |
UPS Topology | Online Double Conversion |
Battery | |
Battery Quantity | 6 |
Battery Size | 12 V / 9 Ah |
Battery Type | Sealed Lead-Acid Battery |
Extended Battery Module | BP72V60ART2U |
Hot Swappable | Yes |
Replacement Battery Cartridge | RB1290X6A |
Replacement Battery Cartridge Quantity | 1 |
Runtime at Full Load | 6.5 min |
Runtime at Half Load | 20 min |
Smart Battery Management (SBM) Mode | Yes |
Typical Recharge Time | 4 Hours (0% to 90% charged) |
Input | |
Circuit Breaker | 20A |
Cold Start | Yes |
Cord Length | 10 ft (3 m) |
Input Frequency Range | 40 Hz – 70 Hz |
Input Plug Type | NEMA 5-20P |
Input Power Factor | 0.99 |
Input Voltage Range | 60 VAC – 69 VAC for 0–60% Load 70 VAC – 79 VAC for 0–70% Load 80 VAC – 89 VAC for 0–80% Load 90 VAC – 95 VAC for 0–90% Load 96 VAC – 150 VAC for 0–100% Load |
Nominal Input Voltage | 100 – 125 VAC |
Output | |
Bypass | Internal Bypass (Automatic and Manual) |
Crest Factor | 3:1 |
ECO Mode Voltage Regulation | ±10%, ±15% (Configurable) |
Harmonic Distortion | < 3% at Linear Load < 5% at Non-Linear Load |
Nominal Output Voltage | 100 – 125 VAC |
On Battery Frequency | 50/60 Hz ± 0.25Hz (auto-sensing or configurable) |
On Battery Voltage | 100/110/115/120/125 VAC ± 2% (configurable) |
On Battery Waveform | Sine Wave |
Outlet Type | 6 – NEMA 5-20R 1 – NEMA L5-20R |
Outlets – Total | 7 |
Output Power Factor | 0.82 |
Overload Protection | Line Mode: 105% ~ 125% Load – 1 min Line Mode: 126% ~ 150% Load – 10 sec Battery Mode: 105% ~ 130% Load – 10 sec Battery Mode: 131% – 150% Load – 2 sec |
Short Circuit Protection | UPS Output Cut Off Immediately or Input Fuse / Circuit Breaker Protection |
Typical Transfer Time | 0 ms |
VA | 2200 VA |
VA by Input Type | 2,200 (2.2 kVA) at 120, 125 V input 1,980 (2.0 kVA) at 115, 110 V input 1,760 (1.8 kVA) at 100 V input |
Watts | 1800 W |
Watts by Input Type | 1,800 (1.8 kW) at 120, 125 V input 1,620 (1.6 kW) at 115, 110 V input 1,440 (1.4 kW) at 100 V input |
Surge Protection & Filtering | |
EMI/RFI Filtration | Yes |
Phone / Network Protection RJ11/RJ45 | 1-In / 1-Out (Combo) |
Surge Suppression (Joules) | 1335 J |
Management & Communications | |
Audible Alarms | Battery Mode Low Battery Overload UPS Fault |
Dry Contacts | Yes |
Emergency Power Off (EPO) Port | Yes |
Expansion Slot | Yes – RMCARD205 pre-installed |
HID Compliant USB Port | Yes |
LCD | Multifunction LCD |
LED Indicators | Power On (White) Line Mode (Green) Battery Mode (Yellow) Bypass Mode (Yellow) Fault (Red) Replace Battery (Red) |
Management Cable | USB Cable Serial Cable |
Removable LCD Control Panel Option | Yes – Requires DB26 cable (not included) |
Rotatable LCD Control Panel Option | Yes |
Serial Port | 1 Serial |
Software (Free Download) | PowerPanel® Business |
Upgradeable firmware | Yes |
Physical | |
Color | Black |
Form Factor | Rack / Tower |
Material of Construction | Metal |
Mounting Hardware | Yes |
Rack Height | 2U |
Dimensions | |
Physical Dimensions – (WxHxD) (cm) | 43.18 x 8.89 x 59.99 (cm) |
Physical Dimensions – (WxHxD) (in) | 17 x 3.5 x 23.62 (in) |
Physical Dimensions – (WxHxD) (mm) | 432 x 89 x 600 (mm) |
Weight (kg) | 30.93 |
Weight (lb) | 68.2 |
Dimensions – Shipping | |
Shipping – Weight (kg) | 39.5 |
Shipping – Weight (lb) | 87.08 |
Shipping Dimensions – (WxHxD) (cm) | 57.15 x 22.86 x 87.63 (cm) |
Shipping Dimensions – (WxHxD) (in) | 22.5 x 9.0 x 34.5 (in) |
Shipping Dimensions – (WxHxD) (mm) | 571.5 x 228.6 x 876.3 (mm) |
Environmental | |
Audible noise at 1m from surface of unit | 38 dBA to 55 dBA (0 to 100% load) |
ECO Mode Thermal Dissipation | 249 BTU/hr |
Online Thermal Dissipation | 541 BTU/hr |
Operating Elevation | 0 – 10000 ft (0 – 3048 m) |
Operating Relative Humidity | 0 – 90 % (non-condensing) |
Operating Temperature | 32 – 104 °F (0 – 40 °C) |
Storage Elevation | 0 – 50000 ft (0 – 15239 m) |
Storage Relative Humidity | 0 – 95% (non-condensing) |
Storage Temperature | -4 – 113 °F (-20 – 45 °C) |
Certifications | |
Environmental | RoHS Compliant |
Safety | UL 1778 CSA C22.2 NO.107.3 FCC Part 15 Class A |
Warranty | |
CEG Amount | $400000 |
Connected Equipment Guarantee | Lifetime |
Extended Warranty Option | WEXT5YR-U4B |
Product Warranty | 3 Year Limited Warranty |