CyberPower
CyberPower OL6KSTF 6KVA/6KW 208V to 120V Step-down Transformer, 2U RT convertible
The CyberPower Smart App Online OL6KSTF rack/tower step-down isolation transformer converts 200 V to 240 V input voltage originating from utility power, a UPS, or a generator to 120 V output.
The OL6KSTF has a capacity of 6,000 VA / 6,000 Watts. It features six (6) NEMA 5-20R receptacles that can support output to NEMA 5-15P and 5-20P plug power cords. A hardwire output terminal block provides a means to connect to an electrical subpanel.
The included 6-foot cord (NEMA L6-30P plug to ROJ) connects the OL6KSTF to input power. Over temperature protection safeguards your OL6KSTF from damage if the internal heat exceeds safe operating parameters.
A Three-Year Warranty ensures that this extended battery module has passed our highest quality standards in design, assembly, material or workmanship.
Step-Down Transformer
- The step-down transformer provides IT managers the ability to support both 120 V and 208 V output requirements. With six (6) NEMA 5-20R outlets available, users will have sufficient outlets to connect multiple 120 V devices running at 15 A and/or 20 A. If additional outlets are needed, CyberPower has a number of different Power Distribution Units (PDU) making it easy to address your specific outlet needs.
NEMA L6-30P Plug
- A 6 foot, 3 wire, power cord with a NEMA L6-30P plug to ROJ (removed outer jacket) is included.
Rack/Tower Versatility
- Allows for horizontal rack or vertical tower installation.
Frequency Supported
- The OL6KSTF has the flexibility to support both 50 Hz and 60 Hz output.
Over Temperature Protection
- Protects the OL6KSTF from damage if the internal heat exceeds safe operating parameters.
Resettable Input and Output Circuit Breakers
- Convenient, resettable switches that provide protection from an input or output overload and faults.
Three Year Warranty
- CyberPower will repair or replace a defective product within three years of the purchase date. See warranty for details.
What’s In The Box
OL6KSTF 2U 6,000 VA Step-down and Isolation Transformer, 6 ft NEMA L6-30 locking male plug to 3-wire ROJ (remove outer jacket) power cable (L630PHW6FT), 2x Terminal block cable glands, Left & right rackmount rails, Left & right hanging brackets, Input/output terminal block cover, Quick Start Guide, Registration Card, 2U rack mount ears (tower stands), Tower installation tie plate, 8x M5X7L black flat head screws, 12x M5X12L black pan head screws, 6x M5X6L silver pan head screws, 8x Plastic washers, 12x Screw hole dust covers, 12x Rubber pads, Safety Instruction Card
WARNING:
This product can expose you to chemicals including Styrene, which are known to the State of California to cause cancer, and Bisphenol A (BPA), which are known to the State of California to cause birth defects or other reproductive harm. For more information go to http://www.P65Warnings.ca.gov.
General | |
---|---|
Type | Step-Down Transformer |
Over Temperature Protection | Yes |
Input | |
Nominal Voltage | 200 V to 240 V |
Frequency | 50/60 Hz |
Current Rating | 30 A |
Plug Type | Hardwire (NEMA L6-30P power cord included) |
Cord Length (ft) | 6 |
Output | |
VA | 6,000 (6 kVA) |
Watts | 6,000 (6 kW) |
Nominal Voltage | 120 V, 208 V |
Frequency | 50/60 Hz |
Outlets – Total | 7 |
Outlet Type | (6) NEMA 5-20R, (1) Hardwire Terminal Block |
Overload Protection | Circuit Breaker Protected |
Physical | |
Form Factor | Rack / Tower Convertible |
Enclosure Construction | Steel |
Rack Mounting Hardware | Included |
Physical Dimensions | |
Dimensions (WxHxD, in) | 17.05 x 3.5 x 24 |
Dimensions (WxHxD, mm) | 433 x 88 x 600 |
Weight (lb) | 95.5 |
Weight (kg) | 43.4 |
Rack Units | 2U |
Shipping Dimensions | |
Dimensions (WxHxD, in) | 23.6 x 13 x 35.4 |
Dimensions (WxHxD, mm) | 600 x 330 x 900 |
Weight (lb) | 128.19 |
Weight (kg) | 58 |
Environmental | |
Operating Temperature | 32°F to 104°F (0°C to 40°C) |
Operating Humidity | 0% to 90% (non-condensing) |
Operating Elevation | 0 ft to 10,000 ft (0 m to 3,000 m) |
Storage Temperature | -4 °F to 113 °F (-20 °C to 45 °C) |
Storage Relative Humidity | 0% to 95% (non-condensing) |
Storage Elevation | 0 ft to 50,000 ft (0 to 15,000 m) |
Thermal Dissipation (100% Load) | 1379 BTU/h |
Audible noise at 1M from surface of unit | 58 dBA |
Compatibility | |
UPS Models | OL3000RTXL2UHV OL3000RTXL2UHV OL5KRTHD OL6000RT3UPDU OL6KRT OL6KRT3UHW OL6KRTHD OL6KRTHW OL6KRTMB OL8000RT3U OL8000RT3UPDU OL8KRT3UHW OL8KRTHW OL8KRTMB OL10000RT3U OL10000RT3UPDU OL10KRT3HW OL10KRTHW OL10KRTMB |
Certifications | |
Safety | UL 1778 5th Ed. CSA C22.2 NO.107.3-05 |
Environmental | RoHS Compliant |
WARRANTY | |
Extended 2-Year Warranty | Optional WEXT5YR-ACC2C |
Product Warranty | 3 Years Limited |